System limitations
The recording system in your MiniDisc recorder is radically different 
from those used in cassette and DAT decks and is characterized by 
the limitations described below. Note, however, that these limitations 
are due to the inherent nature of the MD recording system itself and 
not to mechanical causes.
Symptom
Cause
“TR FULL” 
appears even 
before the disc 
has reached the 
maximum 
recording time 
(60, 74, or 80 
minutes).
When 254 tracks have been recorded on the 
disc, “TR FULL” appears regardless of the total 
recorded time. More than 254 tracks cannot be 
recorded on the disc. To continue recording, 
erase unnecessary tracks.
“TR FULL” 
appears even 
before the disc 
has reached the 
maximum track 
number or 
recording time.
Repeated recording and erasing may cause 
fragmentation and scattering of data. Although 
those scattered data can be read, each fragment 
is counted as a track. In this case, the number of 
tracks may reach 254 and further recording is 
not possible. To continue recording, erase 
unnecessary tracks.
Track marks 
cannot be erased.
The remaining 
recording time 
does not increase 
even after 
erasing 
numerous short 
tracks.
When the data of a track is fragmented, the track 
mark of a fragment under 12 seconds long 
cannot be erased. You cannot combine a track 
recorded in stereo and a track recorded in 
monaural; nor can you combine a track recorded 
with digital connection and a track recorded 
with analog connection.
Tracks of under 12 seconds in length are not 
counted and so erasing them may not lead to an 
increase in the recording time.