The lid does not open 
after recording.
• The lid does not open until “SYSTEM FILE WRITING” disappears 
in the display.
“TRACK FULL” 
appears even before the 
disc has reached the 
maximum recording 
time and the recording 
cannot be done.
• This is due to the MiniDisc system limitation. When 2,047 tracks (on 
a disc used in Hi-MD mode) have been recorded on the disc, 
“TRACK FULL” appears regardless of the total recorded time. More 
than 2,047 tracks cannot be recorded on the disc.
, To continue recording, erase unnecessary tracks.
The remaining 
recording time does not 
increase even after 
erasing numerous short 
tracks.
• This is due to the MiniDisc system limitation (in MD mode only). 
Tracks of under 12 seconds (in SP mode), 24 seconds (in LP2 mode 
or monaural), or 48 seconds (in LP4 mode) in length are not counted 
and so erasing them may not lead to an increase in the recording 
time.
The total recorded time 
and the remaining time 
on the disc may not 
total the maximum 
recording time (60, 74, 
or 80 minutes).
• This is due to the MiniDisc system limitation (in MD mode only). 
Normally, recording is done in minimum units of approximately 2 
seconds (in SP mode), 4 seconds (in LP2 mode or monaural), or 8 
seconds (in LP4 mode). When recording is stopped, the last unit of 
recording always uses this unit of 2 seconds, 4 seconds, or 8 seconds 
even if the actual recording is shorter. Likewise, when recording is 
restarted after the stop, the recorder will automatically insert a blank 
space amounting to 2 seconds, 4 seconds, or 8 seconds before the 
next recording. (This is to prevent accidental erasing of a previous 
track whenever a new recording is started). Therefore, the actual 
recording time will decrease whenever a recording is stopped by a 
maximum of 6 seconds, 12 seconds, or 24 seconds.
“TRACK FULL” 
appears even before the 
disc has reached the 
maximum track 
number or recording 
time.
• This is due to the MiniDisc system limitation. Repeated recording 
and erasing may cause fragmentation and scattering of data. 
Although those scattered data can be read, each fragment is counted 
as a track. In this case, the number of tracks may reach 2,047 (on a 
disc used in Hi-MD mode) and further recording is not possible.
, To continue recording, erase unnecessary tracks.
Symptom
Cause/Remedy
While playing
Symptom
Cause/Remedy
A disc is not played 
normally.
• Repeat play is selected.
, Set the Repeat play to “Off” to change back to the normal play 
• Playback mode is changed.
, Enter the Main play mode or Sub play mode to change back to 
the normal play (page 40).
A disc is not played 
from the first track.
• Disc playing stopped before it came to the last track.
, Press the jog dial (N/ENT) on the recorder or press NX on 
the remote control for 2 seconds or more to start playing.