Sony SAITE1300-F User Manual

Page of 36
Connecting the Optical Fiber Cable for Fibre Channel (SAITe1300-F only) / Turning On the Unit
20
Connecting the Optical 
Fiber Cable for Fibre 
Channel 
 (SAITe1300-F only)
The SAITe1300-F is equipped with an interface that 
complies with the Fibre Channel standards with the 
following specifications.
• Short-wave laser
• 200  MB/sec
• Duplex LC Fibre Channel connectors
The equipment (HBA, hub, switch, etc.) to be connected 
to the SAITe1300-F must be of the same type.
Use an optical fiber cable with the following 
specifications.
• Duplex LC Fibre Channel connectors
• 50/125 
µ
m multimode optical fiber cable
Caution
• If your interface and optical fiber cable are different 
types, the unit may not operate correctly when 
connected.
• Turn off the unit when connecting or disconnecting a 
cable to the fibre channel connector. Failing to do so 
may result in damage.
• Never touch the fibre channel connector of the unit 
when the unit is on. Doing so may result in damage.
Turning On the Unit
1
Press the DOOR button to unlock and open the 
front door.
2
Press the power switch on the front panel.
The POWER indicator lights green and the unit 
starts.
Then four status indicators change as follows as the 
unit is starting.
• All the indicators light green for about half a 
second.
• They then repeatedly flash yellow form left to 
right for about 3 seconds, indicating that the unit 
is performing a self-diagnostic.
• Finally, all the indicators go out. (If there is a 
cartridge in the unit, the TAPE MOTION 
indicator lights green or yellow.)
Caution
• If the POWER indicator flashes when the unit starts, 
the cooling fan of the unit may be malfunctioning. If 
this is the case, verify that the cooling fan on the rear 
is operating normally. If it is not, contact your Sony 
service center.
• If the status indicators do not behave as described 
above, refer to the “Operating Instructions” (PDF).
Host computer or 
HUB, switch, etc.
FIBRE 
CHANNEL
FIBRE CHANNEL
Host bus adaptor 
(FC HBA)
Optical fiber cable for 
fibre channel*
Optical fiber cable for fibre channel*
FIBRE CHANNEL
* 50/125 
µ
m, MMF, Duplex LC