Self-diagnosis function
This monitor is equipped with a self-diagnosis function. If there is 
a problem with your monitor or computer(s), the screen will go 
blank and the 1 (power) indicator will either light up green or 
flash orange. If the 1 (power) indicator is lit in orange, the 
computer is in power saving mode. Try pressing any key on the 
keyboard or moving the mouse.
If the picture disappears from the screen and the 
1
 (power) indicator is green
1
Turn off the 
(power) switch and disconnect the 
video signal cables from the monitor.
2
Turn the monitor on by pressing the 
(power) 
switch.
If all four color bars appear (white, red, green, blue), the monitor 
is working properly. Reconnect the video input cables and check 
the condition of your computer(s).
If the color bars do not appear, there is a potential monitor failure. 
Inform your authorized Sony dealer of the monitor’s condition. 
If the 
1
 (power) indicator lights up in orange
Try pressing any key on the keyboard or moving the 
mouse.
The computer’s power saving mode is awaked and the 1 (power) 
indicator lights up in green, and the picture appears on the screen.
Specifications
LCD panel
Panel type: a-Si TFT Active Matrix
Picture size: 18.1 inch
Input signal format
RGB operating frequency*
Horizontal: 28 – 92 kHz
Vertical: 56 – 85 Hz
Resolution
Horizontal: Max.1280 dots
Vertical: Max.1024 lines
Input signal levels
Analog RGB video signal
0.7 Vp-p, 75 
Ω
, positive
SYNC signal
TTL level, 2.2 k
Ω
positive or negative
(Separate horizontal and vertical, 
or composite sync)
0.3 Vp-p, 75 
Ω
, negative 
(Sync on green)
Digital RGB (DVI) signal: TMDS 
(Single link)
Power requirements
100 – 240 V, 50 – 60 Hz, 
Max. 1.2 A
Power consumption
Max. 58 W
Operating temperature
5 – 35 
°
C
Dimensions (width/height/depth)
Display (upright): 
Approx. 404 
×
 406 
×
 201 mm
(16 
×
 16 
 
×
 8 inches) 
(with stand)
Approx. 404 
×
 332.6 
×
 86.2 mm
(16 
×
 13 
1
/
×
 3 
1
/
2
 inches) 
(without stand)
Mass
Approx. 7.6 kg (16 lb 12 oz) (with 
stand)
Approx. 6.3 kg (13 lb 14 oz)
(without stand)
Plug & Play
DDC2B
Accessories
* Recommended horizontal and vertical timing condition
• Horizontal sync width duty should be more than 4.8% of total 
horizontal time or 0.8 µs, whichever is larger.
• Horizontal blanking width should be more than 2.5 µsec.
• Vertical blanking width should be more than 450 µsec.
Design and specifications are subject to change without notice.
1
 (power) 
indicator