Sony SVT-S480ES User Manual

Page of 196
51
TAPE END OUT Terminal
When the VCR detects the tape end, the output level
becomes 0 V DC. When the buzzer is set to ON on the
DISPLAY/BUZZER/SW OUT menu, the VCR beeps
when the tape reaches its end. To resume the 5 V
output, press the operation button (EJECT Z, REC z,
FF M, REW m, PLAY B or STOP x etc.).
Terminals
COM terminal
 WARNING OUT terminal
Tape recording stops.
Recording
mode
Output
signal
REC mode
Recording
mode
Output
signal
Rewind
Recording
0 V
5 V
Tape end
Beginning of tape
REPEAT REC mode
5 V
0 V
Rewind
Tape end
Beginning of tape
Stop
Press operation
button
COM terminal
TAPE END OUT terminal
To reset the output signal,
press STOP 
x
 or
EJECT 
Z
, or press the reset
button.
2 sec.
WARNING OUT Terminal
This terminal will help you to know when something
wrong has happened to the VCR during recording.
The VCR outputs a pulse signal from WARNING
OUT terminal.
Note
To turn the clog detection function off, set CLOG
DETECTION to OFF on the ALARM SET menu.
5 V
0 V