Sony VPL-EW130 User Manual

Page of 42
23
Indicators
Oth
e
rs
Others
Indicators
The indicators allow checking the status and notify you of abnormal operation of the projector.
If the projector exhibits abnormal status, address the problem in accordance with the table 
below.
?/1 key
LAMP/COVER indicator
Status
Meaning/Remedies
Lights in red
The projector is in Standby mode.
Flashes in green
• The projector is ready to operate after having been turned on. 
• The lamp cools after the projector is turned off.
Lights in green
The projector’s power is on.
Lights in orange
The projector is in Power Saving Mode (lamp cut off). (page 19)
Flashes in red
The projector is in abnormal status. Symptoms are indicated by 
number of flashes. Address the problem in accordance with the 
following. If the symptom is shown again, consult with qualified Sony 
personnel.
Flashes twice
The internal temperature is unusually high. Check the items below.
• Check to see if nothing is blocking the ventilation holes.
• Check to see if the air filter is not clogged. (page 3, page 29)
Flashes six times
Unplug the AC power cord from a wall outlet. After checking that the 
?/1 key goes out, plug the power cord to a wall outlet again then turn 
on the projector.
Other number of 
flashes
Consult with qualified Sony personnel.
Status
Meaning/Remedies
Flashes in red
Symptoms are indicated by number of flashes. Address the problem in 
accordance with the following.
Flashes twice 
The lamp cover or the air filter cover is not attached securely. 
(page 29)
Flashes three times The temperature of lamp is unusually high. Turn off the power and 
wait for lamp to cool then turn on the power again. If the symptom is 
shown again, the lamp may be burnt out. In such a case, replace the 
lamp with a new one (page 27).