Sony VPL-VW50 User Manual

Page of 80
 
56
Warning messages
Caution messages
Message Lists
Message
Cause and Remedy
High temp.! Lamp off in 1 
min.
c Turn off the power.
c Check to ensure that nothing is blocking the ventilation holes. 
Frequency is out of range!
c Frequency is out of range. Input a signal that is within the 
acceptable frequency range of the projector.
Please check Input-A 
Signal Sel.
c Set “Input-A Signal Sel.” in the Setup 
 menu to 
“Computer” when an RGB signal is input from a computer. 
(
Please replace the Lamp/
Filter.
c It is time to replace the lamp. Replace the lamp. (1 page 57)
c Also, replace the air filter too. Restart cleaning the Ventilation 
holes (intake). (
If this message appears again after you replace the lamp and 
filter, the lamp replacement process is not complete. Check the 
lamp replacement process. (
Please clean the filter.
c It is time to clean the air filter. Clean the air filter. (1 page 60)
Please clean the filter. Have 
you finished? Yes No
c It is time to clean the air filter. Clean the air filter. (1 page 60)
c If you cleaned the air filter, select “Yes.” If you did not clean the 
air filter, select “No.”
Projector temperature is 
high.  Cooling Setting 
should be “High”  if 
projector is being used at 
high altitude.
c Check to ensure that the Ventilation holes on the unit are not 
covered. (
c When using the projector at high altitude, set the Cooling 
Setting to “High”. (
When temperature inside the projector remains high, the Cooling 
Setting is switched to “High” in one minute, then the fan speed 
increases.
Message
Cause and Remedy
 
c No signal is input in the selected input. Check connections. 
Not applicable!
c Press the appropriate button.
Note
x