Sony VPL-VW50
55
Oth
e
rs
The ON/STANDBY or LAMP/COVER indicator lights up or flashes if there is any
trouble with your projector.
trouble with your projector.
When a warning indicator other than the above starts flashing, consult with Sony Customer
Information Service Center.
Information Service Center.
Warning Indicators
Symptom
Cause and Remedy
LAMP/COVER flashes in
red. (A repetition rate of 2
flashes)
red. (A repetition rate of 2
flashes)
c Close the lamp cover securely, then tighten the screws securely.
(
1 page 57)
c Close the filter holder securely. (1 page 59)
LAMP/COVER flashes in
red. (A repetition rate of 3
flashes)
red. (A repetition rate of 3
flashes)
c The lamp has reached the end of its useful lifespan. Replace the
lamp. (
c The lamp has reached a high temperature. Wait until the lamp
cools, and then turn on the power again.
ON/STANDBY flashes in
red. (A repetition rate of 4
flashes)
red. (A repetition rate of 4
flashes)
c The fan is broken. Consult with qualified Sony personnel.
ON/STANDBY flashes in
red. (A repetition rate of 2
flashes)
red. (A repetition rate of 2
flashes)
c The internal temperature is unusually high. Check to ensure that
if nothing is blocking the ventilation holes or whether or not the
projector is being used at high altitudes.
projector is being used at high altitudes.
ON/STANDBY flashes in
red. (A repetition rate of 6
flashes)
red. (A repetition rate of 6
flashes)
c Disconnect the AC power cord, then confirm the ON/STANDBY
lamp is turned off. Turn on the power again after re-connecting it.
If the indicators still light up, the electrical system has a problem.
Consult with qualified Sony personnel.
If the indicators still light up, the electrical system has a problem.
Consult with qualified Sony personnel.
Note
LAMP/COVER indicator
ON/STANDBY indicator