Sample Frequency Response Table
for the FIR Filter (4095 tap)
10
0
LEVEL [dB]
–100
–80
–60
–40
–20
10
22050Hz
10k
1k
100
The table above shows the frequency response of the FIR filter (4095 tap) for the
following settings:
Low:  Cut-off frequency 78 Hz, Slope –72 dB/oct.
Mid-L:  Cut-off frequency 78 Hz, Slope –72 dB/oct.
Mid-H:  Cut-off frequency 8 kHz, Slope –24 dB/oct.
High:  Cut-off frequency 8 kHz, Slope –72 dB/oct.