Denon dra-697ci ost-f1289 Service Manual

Page of 1
 
100 Corporate Drive Mahwah, NJ 07430
 
 
       
 
 
 
Service Bulletin
 
No. : 
 OST-F1289 
Date:
 
March 24, 2008 
_____________________________________________________________
 
 
Model:
 
DRA-697CI 
      
 
 
Subject: 
RS232C issue due to MICON software bug.
 
 
 
 
 
 
 
 
 
 
Symptom:
 RS-232C Command Issue for "TF?" and slow port response. 
 
 
Solution:  
The MICON Software has been corrected so that the malfunction 
does not occur.
 
MODIFICATION: 
Install the Writer Software to a PC and update your unit before using Setup Tool, 
by means of the Writer Software. 
1) Download the exclusive Writer Software "FlashWriterD011_TEST.exe" and 
"FlashWriterD011_TEST.exe" to your PC from SDI.  
2) The exclusive Writer Software to be installed to the PC: 
FlashWriterD011_TEST.exe  
3) Turn off the power of DRA-697CI.  
4) Connect RS-232C terminal of PC to RS-232C terminal of DRA-697CI with the 
RS-232C straight cable.  
5) Turn on the power of DRA-697CI.  
6) Select "dra697_m0A62.bin" file at update file of "FlashWriterD011".  
7) Click "Update" button then you will see "OK" sign. 
 
 
 
 
______________________________________________________________________________________ 
CONFIDENTIALITY NOTICE: 
The information contained in this document is intended for the exclusive use by DENON Authorized Service Centers and their 
employees.  This document may contain information that is privileged, confidential and may be protected from disclosure under 
applicable laws and terms of the DENON Service Agreement.  Any distribution, disclosure, dissemination or copying of this 
document and the information it contains is prohibited.  No responsibility will be accepted by DENON for any damage, injury or loss 
resulting from the misuse of the information contained in this document.