Denon s-101 s-301 ost-c1085 Service Manual

Page of 1
 
100 Corporate Drive Mahwah, NJ 07430
 
 
       
 
 
 
Service Bulletin
 
No. : OST-C1085 
Date:
 April 10, 2007 
_____________________________________________________________
 
 
Model:
 
S-101, 
S-301 
      
 
 
Subject: 
Alteration of Transistor TR212.
 
 
 
 
 
 
 
 
 
 
Symptom:
 Transistor TR212 located on the 1U-3694 A/B/C/D/E MAIN P.W.B 
that is used to detect excess current has been changed. The original transistor 
has been replaced with a new style transistor equipped with the built-in Base 
Resistor.  
 
Solution:  
See the parts section for the new part number. 
 
 
Parts: 
 
FORMER NEW 
Ref # 
Description 
Part Number 
Description 
Part Number
TR212 
2SA933(S)-T70  00D 271 0183 
914 
DTA114TS(10K)T 00D 
269 
0080 904 
 
 
 
______________________________________________________________________________________ 