6(b) - RF Troubleshooting
32
COMPANY CONFIDENTIAL
Issue 1 04/2005
Copyright © 2005 Nokia. All Rights Reserved.
The VCO chamber has a fixed shielding lid, which can only be opened by destroying it. To en-
able measurements with a closed lid, holes are located at positions where the supply voltage 
VR7, the tuning voltage Vc and the output frequency f
VCO
 can be measured.
Figure 1:Test holes in the VCO chamber
The VCO frequency has to be measured with a special probe, which fits into the holes of the 
shielding lid. A thin coax cable can be used for this purpose, where the outer conductor is re-
moved for 2mm. The isolation and the inner conductor must fit into the hole of the shielding lid 
and provide a capacitive coupling to the attenuator R7503 at the VCO output. A spectrum an-
alyzer is used to display the frequency.
Figure 2:VCO probe 
The VCO frequency is twice the Rx frequency in the GSM1800 band:
f
VCO
 = 2 * f
RX
 = 2 * 1842.8 MHz = 3685.6 MHz
The tuning voltage can be easily measured at the Vc input of the VCO. The corresponding hole 
in the shielding lid enables the voltage measurement  at C7503, which shows the same DC volt-
age as Vc. 
The tuning voltage should be 2.1V
DC
 .. 2.6V
DC
 at f
VCO
 = 3685.6MHz. 
The tuning sensitivity of the VCO is typically 250MHz/V. The typical relation of VCO frequency 
and tuning voltage is shown in the following diagram: