Nokia 6021 Service Manual

Page of 20
Issue 1 04/2005
COMPANY CONFIDENTIAL
17
Copyright © 2005 Nokia. All Rights Reserved.
RM-94
5 - Disassembly/Reassembly Instructions
Nokia Customer Care
■ 
System connector (X2002)
There are also some marks introduced (bars) in order to help placing the system connector and 
checking placement after rework. The placement bars need to be visible (they can be partly 
hidden by the connector), but the connector must equally hide them in order to be parallel to 
the PWB. In addition, the connectors must meet their pads properly as well.
■ 
UEM (D2200)
There are also corner marks introduced in order to help checking placement after rework.