Troubleshooting 
Page 7  – 55
Original 02/99
UI Troubleshooting
Mechanical Troubleshooting
In mechanical failures it is better to replace a whole unit or module than try
to fix it in service.  The replaceable units or modules on BS2 UI module are:
– BC2 CMT LCD module
– PDA LCD display
– UI PCB
– EL backlight panels
– Keydome sheets
Keyboard Troubleshooting
 – Equipment: Resistance meter (multimeter)
 – If CMT keyboard does not function when the lid is closed, it is possible
that reed relay (in the BS1 module) is damaged. If text ”Please close
cover” comes to CMT LCD when a CMT key is pressed when lid is
closed, the reed relay is probably damaged.
 – Check that the dome sheets are properly placed. Improperly placed
dome sheet may cause malfunction of some key(s) or power down of
the CMT when a key is pressed.
Table 1. CMT keyboard checklist.
Non–functioning CMT keys
Check components
6, 9, #
R704, C707
1, 2, 3, Soft_left
R705, C706
4, 5, Send, Up
R705, C714
7, 8, End, Down
R705, C713
0, *, Mode, Soft_right
R706, C712
3, 6, Send, End, Mode
R706, C708
9, Soft_left, Soft_right, Up, Down
R707, C709
1, 4, 7, #, *
R707, C710
2, 5, 8, 0
R708, C711