Nokia 6230 Service Manual
RH-12/RH-28
Service Software Instructions
CCS Technical Documentation
Page 46
Nokia Corporation
Issue 1 02/04
Select “
Read from Phone” to show current values in the phone memory and to check
that the communication with the phone works.
Select “
Calibrate” to run selected calibrations.
Limits for Energy Management Calibration:
Min
Max
ADC gain
27000
28000
ADC offset
-50
50
BSI gain
930
1100
VBAT gain
10000
11000
VBAT offset
2400
2600
VCHAR
58000
62000
ICHAR
3500
4600
If values shown are within limits, select “
Save To Phone” to save values to phone.
NOTE! Only values of checked tunings (Battery size, Battery Temperature etc…) will be saved.
Close the “
Energy Management Calibration” dialog to end tuning.