Nokia 7270 Service Manual

Page of 118
 RM-8/RM-47/RM-48
Nokia Customer Care
65
COMPANY CONFIDENTIAL
Issue 2  03/2005
Copyright © 2005 Nokia. All Rights Reserved.
The Phoenix window should now look like this:
Now the measurement setup, which has been built according to the chapter 8.1, should detect 
the following output signal of the phone.
P
out
  =  +23dBm @ 836.6 MHz
If this is not the case, then go to the next chapter 8.3.2.1 GMSK for the troubleshooting.
Start the preparations as described in chapter 8.1.
EDGE:
First, select operation mode to the local. Then, select 
→ Testing → RF control.
In the popup window these values are common:
• Active unit 
→ TX
• Band 
→ 850
• Operation mode 
→ Burst
• RX/TX Channel 
→ 190
In the popup window TX control values:
• EDGE 
→ ON
• Tx data type 
→ Alternate
• TX PA mode 
→ High
• TX Power level 
→ 10