Technical Specifications
Modes of Operation
The Communicator has several different operating modes depending on the
activity of CMT and PDA modules. CMT unit can be switched off, idle or call.
PDA can be active, standby, suspended or reset. If the battery voltage is too
low PDA is held in reset–mode.
Electrical Specifications
DC Characteristics
DC–supply for the product is BLN–3 Li–Ion battery. Nominal voltage is 3.6V,
Capacity is 1030mAh i.e. 3708 mWh.
Nominal system voltage for both PDA and CMT is 2.8V.
Average Current Consumption
CMT mode
PDA mode
Off
Idle
Call
Active
90
100
240
Standby
60.5
63
185
Suspended
3.2
5.5
165
Backlight power consumption is 60mA. Handsfree consumes about 80mA.
AC Characteristics
Product contains two EL–panels for CMT and PDA display backlighting.
EL Characteristics, PDA and CMT
Parameter
Minimum
Typical / Nominal
Maximum
Unit
Frequency
60
70
180
Hz
Peak–to–peak voltage
170
175
180
V
RMS voltage
70
72
75
V