1) Setting irradiation conditions 
Setting the irradiation intensity and irradiation time separately for each of CH1 to CH4. 
The
The
The
The 
  
 displayed
displayed
displayed
displayed 
  
 values
values
values
values 
  
 apply
apply
apply
apply 
  
 to
to
to
to 
  
 the
the
the
the 
  
 flashing
flashing
flashing
flashing 
  
 channel.
channel.
channel.
channel.  
  
 
 
 
1. Selecting channels 
Select  the  channel  to  be  set  by  pressing  CH1  to  CH4.  The  selected 
channel is indicated by a green light (flashing or still). 
                                  
* It is not possible to select a CH unless an LED head is connected to it. 
2. Setting irradiation intensity 
Hold  down  the  SET  switch  to  select  the  CH  to  be  set.  (The  selected 
channel  is  indicated  by  a  green  light.)  Initially,  only  “%”  (intensity) 
appears  in  the  green  (7-seg)  display.  Use  △/▽  to  set  the  desired 
intensity value, then press SET again to confirm. Note that while setting 
the irradiation intensity you can press the EMISSION switch to start UV 
irradiation. This makes it easy to make adjustments. 
 
 
3. Setting irradiation intensity 
                                  
When  you  have  finished  setting  the  intensity,  the  green  display  will 
 
automatically  display  only  “sec.”  Use  △/▽  to  set  the  desired  time
 
value, then press the SET switch again to confirm. Note that if you use   
▽  to decrease the setting below “0.0 sec” the display will show “Con.” 
At this setting irradiation will be continuous with no time limit.
 
 
4. Completing settings 
                                 
 After setting irradiation time and pressing SET the controller will return 
  to  Operation  mode.  To  continue  settings  for  other  channels,  repeat  the 
 
                                                                procedure above from step 1 for each channel you wish to set. 
(It  is  possible  to  switch  the  display  even  during  irradiation.  The 
displayed  values  are  stored  in  memory  even  when  the  controller  is 
powered off.  After the controller is powered on again it will restore the 
display to its last state. Note, however, that unless a channel is selected 
nothing will be appeared on the display.) 
2) Timer irradiation 
Irradiation using the EMISSION switch of the controller 
The
The
The
The 
  
 displayed
displayed
displayed
displayed 
  
 values
values
values
values 
  
 apply
apply
apply
apply 
  
 to
to
to
to 
  
 the
the
the
the 
  
 flashing
flashing
flashing
flashing 
  
 channel.
channel.
channel.
channel.  
  
 
  (1) Starting irradiation             
1. Select the channel/s for irradiation. 
  2. Press the EMISSION switch               
(Irradiation will start on all the active channels (green indicator).   
The EMISSION switch glows red during irradiation.) 
                                  
* Irradiation stops after irradiation is finished on all ch
 
annels.
 
                                 
 
 
(2) Stopping irradiation             
3. While irradiation is in progress press the EMISSION switch again. 
 