Operation modes 
 
 
 
17 
6.2
 
UV measurement and Auto tuning mode 
It is possible to make UV measurements and Auto tunings. 
 
* To use this mode it is necessary to have a compatible UV sensor (option).
 
 
■  Operation 
1) Measuring UV intensity 
(1) Connecting a UV sensor            
1. While in operation mode, press the UV CHK switch. 
      2. The intensity setting value (green) and intensity measurement 
                                            value (red) will be displayed. 
                                        3. Select the CH for UV intensity measurement. 
                                                                            4. While the intensity setting value (green) and intensity measurement 
                                                                                value (red) are displayed, hold down the SET switch. 
                                        5. The intensity setting value (green) is displayed. 
6. Use  △/▽  to change the intensity setting value to “---.” 
                                        7. Press the SET switch. 
                                        8. The intensity setting value (green) and intensity measurement 
                                                                              value (red) are displayed. 
                                                                            9.  Press  the  EMISSION  switch  to  start  irradiation  and  begin  the  UV 
intensity  measurement.  The  irradiation  modulation  (%)  and  measured 
intensity value (W/cm2) are displayed. 
10. Press EMISSION again to stop irradiation. 
* Press the MODE switch to switch the measurement range. 
  (0.00 range/00.0 range) 
*  If a measured value exceeds the measurement range the display value   
 
will start flashing. 
(2) Making a UV measurement
 
* It is possible to change the irradiation modulation (%) during a UV   
intensity measurement, using  △/▽.