8  Warning indications 
 
 
46 
In the event of an error during irradiation, a warning will be displayed on the display panel of the controller (in 
operation mode). 
 
■ 
Temperature warning
 
When  the  LED  head  temperature  reaches  the  warning  level  during  irradiation  in  operation  mode,  “TEMP” 
(units  indicator)  will  start  to  flash,  and  the  LED  lights  next  to  the  switch  of  the  affected  channel  will  turn 
orange (mixture of green and red) and the external output signal “ALARM” will be turned ON. 
 
Temperature warning 
When the measured LED head temperature reaches the warning level, “TEMP” 
(units  indicator)  will  start  to  flash,  and  the  LED  light  next  to  the  switch  of  the 
affected  channel  will  turn  orange.  When  the  temperature  reaches  an  abnormal 
level,  an  error  code  (E40)  will  be  displayed  and  the  buzzer  will  sound, and  the 
external output signal “ERROR” will be turned ON. When the temperature drops 
below the abnormal level the warning is cleared and the warning indicators will 
change  back  to  green.  If  the  color  does  not  change  to  green  for  a  considerable 
time, there may be a problem with the LED temperature detection line, such as a 
short-circuit.  In  this  case,  remove  the  LED  head  and the connection cable  from 
the connector and check the wiring. 
■ 
Time warning
 
When  the  warning  time  is  reached  in  operation  mode  during  irradiation,  “×100hrs”  (units 
indicator) will start to flash, and the “ALARM” external output signal will be turned ON. After 
the time warning is detected, “×100hrs” will continue to be displayed until the cumulative time 
(head management item) is reset.
 
Time warning 
When the cumulative total irradiation time of an LED head reaches to within 30 
hours of the set LED replacement time, “×100hrs” (units indicator) will  start to 
flash.  When  the  LED  replacement  time  is  reached,  an  error  (E50)  will  be 
displayed  and  the  buzzer  will  sound,  and  the  external  output  signal  “ERROR” 
will  be  turned  ON.  To  reset  after  this  error,  hold  down  the  “SET”  switch.  This 
will  reset  the  controller  and  turn  OFF  the  buzzer  and  “ERROR”  output  signal, 
but the error code  will still be displayed. The error display  will be cleared only 
after replacing the LED head and resetting the cumulative time.
 
If  irradiation  is  continued  without  replacing  the  LED  head,  the  error  message 
(E50) will be displayed again and the buzzer will sound.
 
*  To  check  which  channels  are  subject  to  time  warnings,  switch  the  display  mode  to  show  cumulative  irradiation  time 
(×100hrs) for the channel. If the “×100hrs” indicator is flashing, the channel is under a time warning.