9  Safety measures 
 
 
 
48 
9.1  Safety circuit 
Aicure UJ35 is equipped with a safety circuit, which functions as follows, in case of a malfunction or accident. 
1) If the cable between the LED head and the controller is broken, an error signal will be output and an error 
screen displayed. 
2) If the LED head is short-circuited, an error signal will be output and an error screen displayed. 
3)  If  the  LED  head  temperature  becomes  excessively  high,  a  warning  signal  will  be  output  with  a  warning 
screen displayed. 
4)  If  5  V  and  GND  are  shorted  by  mistake  during  external  terminal  connections,  the  5  V  circuit  will  stop 
operation. When the short circuit is removed, the controller will automatically recover. Note, however, that 
if the short-circuited state lasts for an extended period, this product may be damaged.