Setup menus 
(continued)
TAPE PROTECT
“_____” indicates the factory setting.
TIME CODE
*1 Displayed menus may vary depending on the settings in
menu No. 25 SYSTEM FREQ. For details, refer to
“Menus which are displayed” (page 32).
*2 Even if the RESET button is pressed while pressing the
SEARCH button, the value may not return to the factory
setting.
No./Item
Description of setting
400
STILL TIMER
For setting the time to be taken before the unit is set 
in the tape protection mode when it is left standing in 
the STOP or STILL status.
(Units: S = seconds, min = minutes)
0000
0.5S
0001
5S
0002
10S
0003
20S
0004
30S
0005
40S
0006
50S
0007
1min
0008
2min
<Note>
When a DV, DVCAM or an unused tape is used, or a 
DVCPRO HD/DVCPRO50/DVCPRO tape is used in 
the EE mode, any setting above 2 (10S) will result in 
a setting time of 10 seconds.
401
SRC 
PROTECT
For setting the operation to be performed in the tape 
protection mode when the unit is left standing in the 
STILL status (JOG/VAR/SHTL).
0000
STEP :
STEP FWD
0001
HALF :
STANDBY OFF (HALF LOADING)
<Note>
When STEP FWD is selected, the unit is 
automatically transferred to the standby OFF (half 
loading) mode when the unit is left standing in the 
STOP mode for a total of 30 minutes (or 1 minute for 
DV or DVCAM tape).
402
DRUM 
STDBY
For setting the cylinder operation in the standby OFF 
(half loading) mode.
0000
OFF
The cylinder stops rotating.
0001
ON
The cylinder continues to rotate.
403
STOP 
PROTECT
For setting the operation to be performed in the tape 
protection mode when the unit is left standing in the 
STOP status.
0000
STEP :
STEP FWD
0001
HALF :
STANDBY OFF (HALF LOADING)
<Note>
When STEP FWD is selected, the unit is 
automatically transferred to the standby OFF (half 
loading) mode when the unit is left standing in the 
STOP mode for a total of 30 minutes (or 1 minute 
for DV or DVCAM tape).
No./Item
Description of setting
500*
1
VITC BLANK
For setting whether to output the VITC signal at the 
position which is set using menu items No.501 VITC 
POS-1 and No.502 VITC POS-2.
0000
BLANK :
The VITC signal is not output.
0001
THRU :
The VITC signal is output.
<Note>
This setting takes effect only with the SD output 
(analog composite output and SD SDI output).
501*
1
*
2
VITC POS-1
For setting the position where the VITC signal is to be 
inserted.
<525 mode>
<625 mode>
0000
10L
0000
7L
    :                        :
    :                        :
0006
16L
0004
11L
    :                        :
    :                        :
0010
20L
0015
22L
<Notes>
z The same line as the one selected by menu item 
No.502 VITC POS-2 and No.692 UMID POS 
cannot be selected.
z This setting takes effect only with the SD output 
(analog composite output and SD SDI output).
502*
1
*
2
VITC POS-2
For setting the position where the VITC signal is to be 
inserted.
<525 mode>
<625 mode>
0000
10L
0000
7L
    :                       :
    :                        :
0008
18L
0008
13L
    :                       :
    :                        :
0010
20L
0015
22L
<Notes>
z The same line as the one selected by menu item 
No.501 VITC POS-1 and No.692 UMID POS 
cannot be selected.
z This setting takes effect only with the SD output 
(analog composite output and SD SDI output).
503*
1
TCG MODE
For setting the synchronization of the internal time 
code generator.
0000
SW :
When the TCG switch on the front panel is set to 
REGEN or PRESET, the selection is complied.
0001
AUTO :
REGEN or PRE is automatically selected 
depending on the operation mode.
When editing (including a chained shot):
REGEN is selected.
Other than the above: PRE is selected.
504*
1
RUN MODE
For setting the operation mode in which the internal 
time code generator runs.
0000
REC :
The generator runs only while recording is in 
progress.
0001
FREE :
The generator runs while the power is on 
regardless of the unit’s operation mode.
505*
1
TCG REGEN
For setting the signal to be regenerated when the 
TCG (time code generator) is in the regeneration 
mode.
0000
TC&UB :
Both the time code and user bits are regenerated.
0001
TC :
Only the time code is regenerated.
0002
UB :
Only the user bits is regenerated.