8.10. Quiet Operation
(For Cooling Operation or cooling region of Soft Dry Operation)
 • 
The Quiet operation is to provide quiet/cooling operation condition compare to normal operation.
 • 
Once the Quiet Mode is set at the remote control, the Quiet Mode LED illuminated. The sound level will reduce around 2 dB
for Lo fan speed or 3 dB for Hi/Me fan speed against the present operation sound level.
 • 
Dew formation become severe at Quiet Lo cool, therefore Quiet Lo cool is operated only 1hr 30 min (1hr QLo, 30 min QLo +
80 rpm). After that, it goes back to Lo cool (However Quiet LED remains on).
 • 
Manual Airflow Direction:-
 − 
RPM control during Lo cool
 − 
RPM control during Hi cool
 • 
Auto Airflow Direction:-
 • 
Quiet operation stops when:-
 − 
Quiet button is pressed again.
 − 
Stopped by OFF/ON operation button.
 − 
Timer OFF activates.
 − 
Powerful button is pressed.
 − 
Economy button is pressed.
 − 
Operation mode button is changed.
25