Panasonic cs-c12dku User Manual

Page of 77
 • 
Remove Control Board cover
Fig. 7
 − 
Remove the screw on the left side of the unit. (Fig.7)
 − 
Pull the hook to the left and lift up the evaporator. (Fig.
7)
 − 
Pull down the Discharge Grille Complete. (Fig.7)
Fig. 8
 − 
Remove indoor pipe sensor and air intake sensor from
the evaporator. (Fig.8)
 − 
Remove 2 screws on the right side of the control board.
(Fig.8)
 − 
Press down the hook on the left side of control board.
(Fig.8)
 − 
Then pull out the Control Board Complete from the unit.
(Fig.8)
Fig. 9
 − 
Remove the cross flow fan bushing from the chassis.
(Fig.9)
 − 
Loosen the fan boss screw at the cross flow fan. (Fig.9)
Fig. 10
 − 
Push up the evaporator and remove cross flow fan by
pulling both cross flow fan and fan motor. (Fig.10)
12.3. Indoor Fan Motor and Cross Flow Fan Removal Procedures
54
CS-C9DKU CU-C9DKU / CS-C12DKU CU-C12DKU