Panasonic cs-c12dku User Manual

Page of 77
How to use electronic circuit diagram
TIMER TABLE
Test Mode
Name
Time
(When test point
Remarks
Short-circuited)
Real Timer
1 hr.
1 min.
10 min.
10 sec.
1 min.
1 sec.
Time Delay Safety Control
2 min. 58 sec.
0 sec.
Forced Operation
60 sec.
0 sec.
Time Save Control
7 min.
4.2 sec.
Anti-Freezing
4 min.
0 sec.
Auto Mode Judgement
20 sec.
0 sec.
Soft Dry
OFF
6 min.
36 sec.
ON
10 min.
60 sec.
Soft Dry: 10 min. operation
Deodorizing Control
Cooling
40 sec.
4 sec.
70 sec.
7 sec.
20 sec.
2 sec.
180 sec.
18 sec.
Soft Dry
40 sec.
4 sec.
360 sec.
36 sec.
Comp. Reverse Rotation Detection
5 min.
30 sec.
Comp. ON 5 min. and above
2 min.
0 sec.
Comp./ Fan Motor Delay Timer
1.6 sec.
0 sec.
Powerful Mode Operation
15 min.
15 sec.
Random Auto Restart Control
0 ~ 62 sec.
0 ~ 6.2 sec.
73