Panasonic cu-3ks19nbu User Manual

Page of 114
25
1 2 3
1 2 3
1 2 3
1 2 3
Indoor unit B
Indoor unit A
Ground
Power:
Single-phase,
230/208VAC 60HZ
Power breaker
(not provided)
Outdoor unit 
Terminal board
Label A
Inter-unit cables
#14 (not provided) 
Terminal board
Inter-unit cables
#14 (not provided) 
Terminal board
Label B
Label C
Inter-unit cables
#14 (not provided) 
Inter-unit cables
#14 (not provided)
Terminal board
Terminal board
Label D
A
B
C
D
Power cable (not provided) 
(#12: Less than 85 ft.)
Be sure to perform grounding.
Attach a ground wire to either the
outdoor unit or indoor unit.
If there is a grounding terminal
inside the room, use the grounding
screw inside the indoor unit.
Be sure to apply the provided labels to both
ends of the inter-unit cables to prevent mis-
wiring. The units will not function if the wiring
connections are incorrect.
 A  is the indoor unit with 
refrigerant tubing that is 
connected to service valve 
A (bottom) of the outdoor unit.
refrigerant tubing that is 
connected to service valve B 
(second from the bottom) of 
the outdoor unit.
 B  is the indoor unit with 
Indoor unit C
refrigerant tubing that is 
connected to service valve 
C (third from the bottom) 
of the outdoor unit.
 C  is the indoor unit with 
Indoor unit D
refrigerant tubing that is 
connected to service valve 
D (top) of the outdoor unit.
 D  is the indoor unit with 
1     2
1   2   3   4   5   6   7   8   9  10 11 12
Power supply
(conduit)
Inter Unit
(conduit)
Inter Unit
(conduit)
# ... AWG (American Wire Gauge)
5-5.  Wiring Instructions for the Outdoor Unit
Be sure to correctly align inter-unit cables A, B, C and D.
Use a dedicated air conditioner circuit for power.
To make connections to the outdoor unit, remove the inspection panel and tubing panel.
Do not bring the inter-unit cables or power cable into contact with tubing or service valves.
Use outdoor unit cable fasteners and fasten the inter-unit cables at the location where the cables are double-
sheathed.
Arrange the wiring so that the inter-unit cables are contained in the inspection panel and tubing panel, as shown in
Fig. 31.
CAUTION
Fig. 31