Panasonic cu-ks30nkua User Manual

Page of 108
Outdoor Unit :
CU-KS30NKUA
Indoor Unit  :
CS-KS30NKU
Power supply : 230V Single Phase 60Hz
 RATING CAPACITY:   
30,600 BTU/h
      AIR FLOW RATE:
630 CFM
INDOOR
OUTDOOR
 ENT. TEMP. 
o
F (
o
C)
    AMBIENT TEMP. 
o
F (
o
C)
WB
DB
0
5
15
25
35
45
55
(-17.8)
(-15.0)
(-9.4)
(-3.9)
(1.7)
(7.2)
(12.8)
TC
30,120
30,060
29,930
29,780
29,590
29,330
29,070
CI
0.05
0.19
0.47
0.74
1.01
1.33
1.61
72 (22.2)
SHC
21,150
21,150
21,020
23,230
20,780
20,660
20,530
59
76 (24.4)
SHC
23,470
23,470
23,350
25,550
23,230
22,980
22,860
(15.0)
80 (26.7)
SHC
25,920
25,920
25,790
27,870
25,670
25,430
25,300
84 (28.9)
SHC
28,240
28,240
28,120
29,780
27,990
27,870
27,630
88 (31.1)
SHC
30,120
30,060
29,930
29,780
29,590
29,330
29,070
TC
30,390
30,360
30,270
30,170
30,040
29,820
29,610
CI
0.12
0.25
0.52
0.79
1.06
1.38
1.66
72 (22.2)
SHC
17,720
17,720
17,600
23,230
17,480
17,360
17,360
63
76 (24.4)
SHC
20,050
20,050
19,920
25,550
19,800
19,800
19,680
(17.2)
80 (26.7)
SHC
22,490
22,490
22,370
27,870
22,370
22,250
22,120
84 (28.9)
SHC
24,820
24,820
24,820
30,170
24,690
24,570
24,450
88 (31.1)
SHC
27,140
27,140
27,140
30,170
27,020
26,890
26,770
TC
30,490
30,480
30,450
30,400
30,330
30,160
30,020
CI
0.20
0.33
0.60
0.86
1.13
1.45
1.73
72 (22.2)
SHC
14,180
14,180
14,180
23,230
14,180
14,050
14,050
67
76 (24.4)
SHC
16,500
16,500
16,500
25,550
16,500
16,380
16,380
(19.4)
80 (26.7)
SHC
19,070
18,940
18,940
27,870
18,940
18,820
18,820
84 (28.9)
SHC
21,390
21,390
21,390
30,200
21,270
21,150
21,150
88 (31.1)
SHC
23,710
23,710
23,710
30,400
23,590
23,590
23,470
TC
30,370
30,380
30,410
30,430
30,420
30,310
30,250
CI
0.31
0.43
0.69
0.95
1.21
1.54
1.81
72 (22.2)
SHC
10,510
10,510
10,510
23,230
10,630
10,510
10,510
71
76 (24.4)
SHC
12,950
12,950
12,950
25,550
12,950
12,830
12,830
(21.7)
80 (26.7)
SHC
15,400
15,400
15,400
27,870
15,400
15,280
15,280
84 (28.9)
SHC
17,720
17,720
17,720
30,200
17,720
17,720
17,600
88 (31.1)
SHC
20,050
20,050
20,050
30,430
20,050
20,050
20,050
TC
30,030
30,080
30,170
30,240
30,310
30,250
30,270
CI
0.42
0.55
0.79
1.04
1.30
1.62
1.89
75
76 (24.4)
SHC
9,410
9,410
9,410
25,550
9,530
9,530
9,530
(23.9)
80 (26.7)
SHC
11,850
11,850
11,850
27,870
11,970
11,970
11,970
84 (28.9)
SHC
14,180
14,180
14,300
30,200
14,300
14,300
14,300
88 (31.1)
SHC
16,500
16,620
16,620
30,240
16,620
16,620
16,620
TC   : Total Cooling Capacity    (BTU/h)
SHC  : Sensible Heat Capacity (BTU/h)
5-3.  Cooling Capacity (Low Ambient)
1.
2. Above data represents the value when the operation frequency of a compressor is fixed.
Above data does not take Freeze Prevention Protection during cooling operation into account. 
For this reason, the value may vary from the actual cooling characteristics.
NOTE
< Cooling Capacity (Low Ambient) >
23