Panasonic gpf12d th-85pf12u Service Manual
46
TH-85PF12U
10.1.2.
Initialization Pulse Adjust
1. Set Aging pattern (white pattern signal) by IIC mode.
2. Set the picture controls as follows.
2. Set the picture controls as follows.
Picture menu: Standard
Picture: +25
Aspect: Full
Picture: +25
Aspect: Full
3. Connect Oscilloscope to TPSC1 and adjust VR16601 for 125V ± 5V.
Test Point
Volume
Level
TPSC1 (SC)
VR16601 (SC)
125V ± 5V
at 50
at 50
µs
period on the down slope.