Panasonic gp8du gph8du th-37px50u th-42pd50u th-42px50u th-42px500u th-50px50u th-50px500u troubleshooting Service Manual

Page of 85
P Board SOS Detection 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 43 
 
 
This drawing is used to verify an SOS condition that may have originated from the P 
Board. The connector information should be used for troubleshooting purposes. The 
switched voltages of connector P23 and P5 are monitored on the SC and PB boards. 
The remaining voltages are monitored for abnormalities directly on the P board. Instead 
of using a peak hold voltmeter, the power supply connector of the suspected board 
causing the blinks of the power LED may be disconnected to see if the unit remains on 
after power up. If it does, this usually indicates that the problem is located in the 
disconnected board. If the power LED continues to generate the same amount of blinks, 
more troubleshooting is required.  
 
Note: The unit will become totally inoperative if the connector P10 is disconnected. The 
system control circuit will be unable to power the unit. The power LED will blink ten 
times immediately after connecting the unit to the wall outlet. 
 
 