Panasonic gp6d th-42px20u th-50px20u th-42pa20u th-37pa20u update information Service Manual

Page of 70
 
P.C.B. (Printed Circuit Board) exchange procedure 
1. Caution 
 Wait 1 minute for the electrolytic capacitors to discharge before removing 
any PCB from the unit.  
 
2. Quick adjustment after P.C.B. or Panel exchange 
P.C.B. 
Item 
Volume 
Test point 
Voltage level 
Panel 
All items in this table 
Vsus 
R605 (P-Board) 
TPVsus (SS) 
Vsus ± 1V* 
P Board 
Vda 
R590 (P) 
TPVDA (SS Board) 
67V ± 1V 
Vbk 
R6443 (SC) 
TPVBK (SC) 
155V ± 5V* 
Vad 
R6477 (SC) 
TPVAD (SC) 
-90V ± 1V* 
Vset TPVSET 
(SC-BOARD) 
218 V ± 6V 
Verify Only 
SC Board 
VSCN TPVSCN 
(SC-BOARD) 
Vad+118V ± 2V 
Verify only 
SS Board 
Ve 
R6774 (SS) 
TPVE (SS) 
Ve ± 1V* 
D, DG Board 
White Balance, Pedestal and Sub brightness for NTSC, Pal, HD, PC and 625i 
signals 
*Refer to the Panel label for the exact value. 
 
Adjustment Volume Locations 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 37 
 