4.1 Troubleshooting
Installation Manual
173
4.1.5
Troubleshooting by Error Log
When a major system error occurs in the Hybrid IP-PBX, the ALARM indicator on the front of the shelf turns 
on red, and the system logs the error information.
Error Log Display Format
Below is the display format of the error log. To see the error log using the KX-TDA Maintenance Console, 
refer to the on-line help of the KX-TDA Maintenance Console.
Example: KX-TDA Maintenance Console
Example: Station Message Detail Recording (SMDR)
Description
Item
Description
1
Date
Date of the error detection
2
Time
Time of the error detection
3
Level
Major Alarm (MJ ALM):
Errors that affect the whole system operation, or result in system 
failure
Minor Alarm (MN ALM):
Errors that affect certain part of system operation
4
Error Code
Three-digit error code
1
2
4
5
6
3
04/01/01 10:37AM  MJ  ALM #000 10000  MPR WDT overflow    
04/01/01 11:07AM  MN ALM #010 10000  AC power down      
04/01/01 03:55PM  MN ALM #301 10501  Digital trunk RAI reception
1
2
3
4
5