Panasonic KX-TDE100 User Manual

Page of 252
1.4 Specifications
32
Installation Manual
1.4.2
Characteristics
Terminal Equipment Loop Limit
PT: KX-T7600 series DPT: 90 
Ω; all other DPTs/APTs: 40 Ω
SLT: 600 
Ω including set
Doorphone: 20 
Ω
CS: 130 
Ω; PT-interface CS (Basic/High-density): 65 Ω
Minimum Leakage Resistance
15 000 
Ω minimum
Maximum Number of Extension 
Instruments per Line
for PT or SLT
by Parallel or eXtra Device Port connection of an APT/DPT and an SLT
by Digital eXtra Device Port connection of 2 DPTs and an SLT
Ring Voltage
75 Vrms at 20 Hz/25 Hz depending on the Ringing Load
Trunk Loop Limit
1600 
Ω maximum
Hookswitch Flash/Recall Timing 
Range
24 ms to 2032 ms
BRI Cards Internal ISDN Mode
Supply Voltage: 40 V
Power Supply (BRI4): 4.5 W per 1 line, 10 W per 4 lines
Power Supply (BRI8): 4.5 W per 1 line, 20 W per 8 lines
Power Supply Method: Phantom Power Supply
Door Opener Current Limit
24 V DC/30 V AC, 1 A maximum
External Relay Current Limit
24 V DC/30 V AC, 1 A maximum
External Sensor Current Limit
Power to the external sensor is provided from the EIO4 card and must be 
grounded through the EIO4 card. For the connection diagram, refer to 
"3.7.4 EIO4 Card (KX-TDA0164)". The PBX detects input from the sensor 
when the signal is under 100 
Ω.
Paging Terminal Impedance
600 
Ω
MOH (Music on Hold) Terminal 
Impedance
10 000 
Ω