Panasonic KX-TDE100 User Manual

Page of 54
3.1  Programming the V-SIPGW16 Card—Port
Property
Various settings can be programmed for each virtual SIP gateway port. To change the status of virtual SIP
gateway ports, click Command.
Accessing Port Properties
1.
Under Configuration, click Slot.
2.
Move the mouse pointer over the white PBX image at the bottom of the screen for the virtual slots.
3.
Click Select Shelf.
4.
Move the mouse pointer over the V-SIPGW16 card.
5.
Click Port Property.
Programming Port Property
Some of the parameters can be automatically programmed by selecting the desired SIP provider for each
virtual SIP gateway port.
Icon Description
In this section, the following icons show the different parameter type.
Icon
Description for Parameter Type
Programmed automatically by selecting the desired SIP provider in Select Provider.
Manual programming is compulsory.
Manual programming is compulsory under certain conditions.
Not marked
Manual programming is optional.
Automatic Programming
Some of the parameters on this screen can be automatically programmed by selecting the desired SIP provider
for each virtual SIP gateway port. A maximum of 32 SIP providers can be programmed, and a different SIP
provider can be assigned to each virtual SIP gateway port.
Follow the steps below to configure a SIP provider.
1.
Click Select Provider.
A dialogue box will appear. Available virtual SIP gateway port numbers are displayed in the list.
2.
From the Provider menu, select the desired SIP provider.
3.
Highlight the desired port numbers or click Select All to select all the virtual SIP gateway port numbers to
be assigned to the SIP provider selected in step 2.
4.
Click Execute.
5.
Click OK.
6.
Click Apply.
Appropriate setting values designated by the SIP provider will be set in the parameters for the virtual SIP
gateway ports.
Manual Programming
Follow the steps below to programme the parameters which are not automatically programmed by selecting a
provider.
1.
Click a desired tab.
18
Programming Manual for Virtual SIP Trunk Card
3.1 Programming the V-SIPGW16 Card—Port Property