Preparations 
and 
Adjustments
1k
Ω
1k
Ω
SP
1
2
3
IM
GND
Measuring 
instrument 
or external 
circuit
CN MON
19
14
CZ
Maximum rating: 
30V, 50mA
GND
High-speed 
photo coupler
TOSHIBA TLP554 or equivalent
Analogue  Monitor  Output
•  Output from CN MON Connector
•  This output is the velocity monitor signal
(SP) or torque monitor signal (IM).
•  The signal range is approx.  0 to 9V.
•  The output impedance is 1kΩ. Pay atten-
tion to the input impedance of your mea-
suring instruments and
      external  circuits  connected.
<Resolution>
1) Velocity monitor signal (SP): 8r/min./
LSB  calculated  from  6V/3000r/min
(Pr07 = 3)
2) Torque monitor signal (IM): 0.4%/LSB
calculated from 3V/rated value (100%)
A O
Open  Collector  Output
•  Outputs Z-phase signals among those
from the encoder. The outputs are non-
insulated.
•  Receive these signal with high-speed
photo coupler at controller side, since
these Z-phase signal width is normally
narrow.
P O 2
shows a pair of twisted  wires.
CN  MON  Connector
Monitor  Circuit  (Output  Circuit)