Important 
information
Overvoltage
error
1) The internal regenerative discharge
resistor is disconnected.
2) The external regenerative discharge
resistor is not suitable so that regenerative
energy cannot be absorbed.
3) The amplifier (circuit) failed.
1) Measure the resistance value of the exter-
nal resistor installed between P and B am-
plifier terminals using a tester.  If it read Åá,
the connection is broken.  Replace the ex-
ternal resistor.
2) Use a resistor having the specified resis-
tance for specified rated power.
3) Replace with a new amplifier.
1 2
The  line  voltage  is  larger  than  the
specified  acceptable  range,  so  that
the  P-N  voltage  of  the  converter  is
larger  than  the  specified  value,  or
the  line  voltage  was  raised  by  a
advancing  capacitor  or  UPS
(Uninterruptible  Power  Supply).
Measure  the  terminal-to-terminal  volt-
ages  (between  L1,  L2  and  L3).  Re-
move  the  causes.  Feed    a  power  of
correct  voltage.  Except  phase  ad-
vancing  capacitor
Undervoltage
Protection
C a u s e
Alarm
Code No.
1 1
The  P-N  voltage  of  the  main  power
converter  is  lower  than  the  specified
voltage  during  Servo-ON.
1) The main power line voltage is too low.
An instantaneous outage occurred.
2) Too small power source: The line voltage
dropped due to the in-rush current at
power on.
3) Open phase: Operating with a single
phase from the main power in spite of 3-
phase specifications.
4) The amplifier (circuit) failed.
Measure  the  terminal-to-terminal  volt-
age  (between  L1,  L2  and  L3).
1)  Increase  the  capacity  of  the  main
power or replace it with a larger one.
Or remove the causes of the failure
of the magnetic contact, and then re-
start the power source.
2)  Increase  the  capacity  of  the  main
power. For the required capacity, see
"List of Applicable Equipment".
3) Correct the phase (L1, L2 and L3) con-
nection of the main power. If the main
power is single-phase 100V or single-
phase 200V, use L1 and L3.
4) Replace with a new amplifier.
C o u n t e r m e a s u r e s
Protective  Functions:  Causes  and  Corrections