Panasonic PT-AR100U User Manual

Page of 94
[PICTURE] menu
40 - ENGLISH
Settings
Adjust the waveform
 
Project the brightness adjustment signal of a commercial 
test disk (0% [0 IRE or 7.5 IRE] - 100% [100  IRE] ) and 
perform adjustment.
 
RETURN
MOVE DISPLAY
CHANGE WF MODE
Adjust to 100%
Signal (luminance) level
Signal (luminance) level
Monitor 
position
Monitor 
position
Adjust to 100%
Adjust to 0 %
With COMPUTER (except 1 080 
signal) or HDMI (Expand)
Adjust to 0 %
Image 
displayable 
area
Image 
displayable 
area
With the [WAVEFORM MONITOR] displayed, press the 
<MENU> button on the remote control and adjust using 
[ADVANCED MENU] and [PICTURE] from the on-screen 
menu.
Adjust [FULL SCAN(Y)] / [SINGLE LINE 
1)  
SCAN(Y)].
Set on [PICTURE] and use the 
 
z
▲ ▼  buttons to 
adjust [BRIGHTNESS] and then [CONTRAST].
[BRIGHTNESS]
Adjust the bottom line of the 
waveform to 0 %  
(0 or 7.5 IRE)
Setting range:  
 
z
−32 to +32
[CONTRAST]
Adjust the top line of the 
waveform to 100 %  
(100 IRE)
Setting range:  
 
z
−64 to +64
Adjust [FULL SCAN(R)] / [SINGLE LINE 
2)  
SCAN(R)].
Set on [ADVANCED MENU] and use the 
 
z
▲ ▼  
buttons to adjust [BRIGHTNESS R] and then 
[CONTRAST R].
[BRIGHTNESS R]
Adjust the bottom line of the 
waveform to 0 %  
(0 or 7.5 IRE)
Setting range:  
 
z
−16 to +16
[CONTRAST R]
Adjust the top line of the 
waveform to 100 %  
(100 IRE)
Setting range:  
 
z
−32 to +32
Adjust [FULL SCAN(G)] / [SINGLE LINE 
3)  
SCAN(G)].
Set on [ADVANCED MENU] and use the 
 
z
▲ ▼  
buttons to adjust [BRIGHTNESS G] and then 
[CONTRAST G].
[BRIGHTNESS G]
Adjust the bottom line of the 
waveform to 0 %  
(0 or 7.5 IRE)
Setting range:  
 
z
−16 to +16
[CONTRAST G]
Adjust the top line of the 
waveform to 100 %  
(100 IRE)
Setting range:  
 
z
−32 to +32