Copper wire
#24
#22
#20
#18
size (AWG)
(0.22mm
2
)
(0.33mm
2
)
(0.52mm
2
)
(0.83mm
2
)
Resistance
0.078
0.050
0.030
0.018
Ω
/m
Resistance
0.026
0.017
0.010
0.006
Ω
/ft
-8-
A. WV-CL830 (220 - 240V AC 50Hz)
1. Connect the AC power cord (supplied as standard
accessory) to the power cord socket of the cam-
era.
era.
2. Connect the AC power cord to an electrical outlet
of 220 - 240V AC 50 Hz.
Notes:
• Connect the power cord firmly.
• The power cord should be long enough for pan-
• The power cord should be long enough for pan-
ning and tilting.
If the cable is too short, the power cord plug may
pulled off the camera when the camera pans or
tilts.
If the cable is too short, the power cord plug may
pulled off the camera when the camera pans or
tilts.
B. WV-CL834 (12V DC/24V AC)
The WV-CL834 has an AC/DC compatible input termi-
nal. The 12V DC or 24V AC power supply cord can be
connected to this terminal. The camera detects the
power source automatically.
nal. The 12V DC or 24V AC power supply cord can be
connected to this terminal. The camera detects the
power source automatically.
1. 12 V DC Power Supply
Connect the power cord to
the AC/DC compatible
input terminal on the rear
panel of the camera.
the AC/DC compatible
input terminal on the rear
panel of the camera.
Resistance of copper wire [at 20°C (68°F)]
AC 24V
IN
DC 12V
IN
1
2
GND
12 VDC
(10.5 V - 16 V)
(10.5 V - 16 V)
• Calculation method of maximum cable length
between camera and power supply.
10.5V DC
≤
V
A
−
(R x 0.42 x L)
≤
16V DC
L : Cable length (meter)
R : Resistance of copper wire (
Ω
/meter)
V
A
: DC output voltage of power supply unit
V
A
−
12
L standard =
(meters)
0.42 x R
V
A
−
16
L minimum =
(meters)
0.42 x R
V
A
−
10.5
L maximum =
(meters)
0.42 x R