Panasonic ty-la1000k User Manual

Page of 2
 WARNING:
  The lamp may be hot. Be careful when handling. 
 CAUTION:
  • High-pressure lamp may explode if improperly 
handled.
• Danger of injury due to glass fragments. 
 ■ Lamp replacement procedure 
 1
Turn power off, wait until power 
indicator stops blinking red, then 
unplug the power cord from the wall 
outlet and confi rm that the area around 
the lamp unit has cooled down. 
 • Please wait more than one hour for lamp 
replacement.
   [If you need to replace the lamp more urgently]
  • The Projection display has a forced cooling 
feature. After the POWER button is turned OFF, 
and during the fi rst minute of the normal cooling 
fan operation, press the VOL+ button on the 
projection display and ▲ button on the remote 
control at same time for more than 5 seconds. The 
cooling fan operates for about 10 minutes. The 
LAMP indicator fl ashes red 5 times every 5 
seconds. 
 POWER 
button 
/POWER 
indicator 
 Lamp Replacement 
 3
Loosen the Lamp cover screw.
First read caution and warning labels 
on lamp cover. Then, loosen the lamp 
cover screw by using a screwdriver. 
 Lamp unit screw 
 Screwdriver 
 4
Loosen the lamp unit screw with a 
screwdriver. Then, grasp the lamp unit 
as shown in the diagram, and slowly 
remove from the projection display.
  • Do not drop, as the impact of dropping may cause 
the lamp to explode. 
 2
Remove the Front cover. Place your 
fi ngertips under the Front cover and 
pull it from the projection display. 
 Lamp unit handle 
 Lamp cover handle 
 6
Replace the Lamp unit and cover 
screws. Tighten the lamp unit/cover 
screw with a screwdriver.
  • Properly dispose of old lamp. 
 Attach the lamp unit and lamp unit housing door 
securely.  If the lamp unit and lamp unit housing 
door are not attached securely, the protective 
circuit will be activated and the lamp will not turn 
on.  
 Note 
 7
Replace the Front cover. 
 5
Insert the new lamp unit being careful 
of the insertion direction.
  • Press on the arrow mark making sure insertion is 
done correctly. 
 ■ Lamp time reset procedure 
 1
Be sure the power cord is plugged into 
a properly grounded wall outlet. Then, 
press the POWER button on the projection 
display or the remote control to turn the 
unit on. 
 Warning:
Perform lamp time reset only when the lamp has 
been replaced. 
 When lamp time reset is fi nished, the LAMP 
indicator goes out. 
 Note 
 After lamp replacement, 
follow the procedure below 
 3
When reset 
procedure is 
complete, the 
screen on the right 
will appear. 
 and 
 Lamp cover screw 
 LAMP  indicator 
 2
While pressing the VOL- button on 
the projection display, hold down the 
PIP button on the remote control at 
same time for more than 5 seconds. 
 
LSQC0335 
 CAUTION:
[Under no circumstance should you touch the 
actual bulb.]
  At this high operating temperature the natural oil 
on your fi nger can cause the glass to weaken 
where touched and the bulb can crack or explode. 
 CAUTION:
  Because of the possibility of injury, strictly follow the 
replacement procedure below. 
      LAMP TIME WAS
       RESET TO 0.
                EXIT
 Front  cover