Specifications
Model Number
Type
Power Source
Voltage
Electric current
Supply system
Touch Panel
Detection system
Panel window (W 
× H)
Detection range (W 
× H)
Effective detection range
Operating modes
Resolution (W 
× H)
Detection pitch
Output system
Number of optic elements (W 
× H)
Optic element pitch (W 
× H)
Minimum stylus size (W 
× H)
Scan speed
Touch pen
USB Interface (USB 1.1)
Temperature
Humidity
Resistance to extraneous light
Panel form
External dimensions (W 
× H × T)
Weight
Extruded material
                          TY-TP42P6-S
TY-TP50P6-S
Optic Touch Panel
DC + 5 V 
± 10 %
DC + 5 V Max 400 mA under
from USB Bus Power (DC + 5 V Max 500 mA)
Infrared obstruction detection system
928.5 mm 
× 526.5 mm (36.55 ″ × 20.73 ″)
1,118 mm  
× 632 mm (44.02 ″ × 24.88 ″)
916 mm  
× 516 mm (36.06 ″ × 20.31 ″)
1,100 mm  
× 620 mm (43.31 ″ × 24.41 ″)
Detection range + 1.0 mm (0.04 
″) at the top, bottom, left and right
Detection operation at input point, during initial movement and at end point 
 ∗
1
1,833 
× 1,033  
1
2,201 
× 1,241  
1
2.0 mm 
× 2.0 mm (0.08 ″ × 0.08 ″)
Coordinate output
230 
× 130 elements
276  
× 156  elements
4.0 mm  
× 4.0  mm (0.16 ″ × 0.16 ″)
6.0 mm 
× 6.0 mm (0.24 ″ × 0.24 ″)
Initial touch: 30 ms/frame max.;       during movement: 8 ms/frame max.
Infrared system
When operating: 0
°C (32°F) to 50°C (122°F) (temperature gradient 25°C (77°F)/hr max.) 
  ∗
2
When not operating: -10
°C (14°F)  to 60°C (140°F) temperature gradient 25°C (77°F)/hr max.
When operating: 20% to 85% (must be no condensation) 
  ∗
2
When not operating: 10% to 95%
Lateral light: 2,000 lx MIN +20% (angle of incidence: 20
°)
Frontal light: 10,000 lx MIN +20% (angle of incidence: 90
°)
Flat panel (Flat type)
1,066 mm  
× 634 mm × 69 mm
1,256 mm  
× 748 mm × 69 mm
(41.97 
″ × 24.96 ″ × 2.72 ″)
 (49.45 
″ × 29.45 ″ × 2.72 ″)
(Excluding mounting brackets)
(Excluding mounting brackets)
3.5 kg (7.7 lbs) Excluding mounting brackets
4.2 kg (9.3 lbs) Excluding mounting brackets
Aluminum
Notes:
∗1   When it is used with exclusive driver software.
∗2   This applies to the touch panel alone. When the panel is attached to a device such as a PDP, follow the
environmental conditions for the device being used.
Terminal No. and Signal name
1
2
4
3
1
  Vcc
-DATA  
2
+DATA  
3
4
  GND
(TYPE B)