Panasonic wj-hd220 User Manual

Page of 104
67
Parity Check (PARITY CHECK)
NONE: No parity check
EVEN: Even parity
ODD: Odd parity
Stop Bit (STOP BIT)
1 bit: 1 bit
2 bit: 2 bits
Wait Time (WAIT TIME)
OFF: Retransmission is disabled.
100 MSEC: 100 m seconds
200 MSEC: 200 m seconds
1 SEC: 1 second
Control Unit Addresses 
(CONTROL UNIT ADDRESS) (only for PS
DATA)
Assignable address: From 1 to 99, must be unique in
the chain.
System Unit Address (SYSTEM UNIT ADDRESS) 
(only for PS
DATA)
Assignable addresses: From 1 to 99, must be unique
in the chain.
Alarm Data (ALARM DATA)
OFF: Select this when no system controller is connect-
ed.
0 SEC: Does not pause.
1 SEC: Pauses for 1 second.
5 SEC: Pauses for 5 seconds.
Click the [SET] button when all items have been set proper-
ly.
Click the [CAMERA SYSTEM SETUP] button. The CAMERA
SYSTEM SETUP window opens.
■ Communication Setup
(COMMUNICATION SETUP)
Click the [SERIAL PORT SETUP] or [NETWORK SETUP]
button. The respective window opens.
■ Serial Port Setup 
(SERIAL PORT SETUP)
Protocol Selection (PROTOCOL SELECT)
PS
DATA:  Select when the communication chain uses
the PS
DATA protocol.
When selected, the DATA terminal on the rear panel
can be used.
RS-232C: Select when other than PS
DATA is used. 
When selected, the RS-232C terminal on the rear
panel can be used.
Baud Rate (BAUD RATE) 
4800: 4 800 bps
9600: 9 600 bps
19200: 19 200 bps
Data Bit (DATA BIT) 
7: 7 bits 
8: 8 bits