Panasonic WV-BM500 User Manual

Page of 14
-7-
CONNECTIONS
Power Cable
1. Keep the camera Power switched OFF during
installation.
2. Connect the Power Cord (16) to a 50 Hz grounded
electrical outlet 220-240V AC .
Video Cable
1. Use the RG-59/U (3C-2V), RG-6/U (5C-2V). RG-
11/U (7C-2V) or RG-15/U (10C-2V) coaxial cable.
2. Up to 10 monitors can be hooked up in this config-
uration before signal loss occurs. Total cable
length should not exceed 500 feet (150m).
3. Wiring Precautions
• Do not bend coaxial cable into a curve whose
radius is smaller than 10 times of its diameter.
• Never crush or pinch the cable
All these will change the impedance of the cable
and cause poor picture quality
Cable
RG-59/U
RG-6U
RG-11/U
RG-15/U
(3C-2V)
(5C-2V)
(7C-2V)
(10C-2V)
Recommended
(m)
500
750
1000
1250
maximum
cable length
(ft)
1650
2475
3300
4125
Recommended maximum cable length
External Sync
When a non-composite video signal is connected to
the monitor, it will be necessary to connect an external
composite sync signal to the monitor.
1. Connect the Sync Input Connector (14) on the
video monitor to the sync signal source by means
of a 75
Ω
coaxial cable.
2. Set the Sync Selector Switch (13) at EXT position.
NOTE:
1. Non-composite video signal is a signal without
sync.
2. External sync should be composed of mixed H.
Sync and V. sync signals, not H. and V. drive
pulse signals. Composite Sync Level:
4.0 Vp-p (2.0 Vp-p 
5.0 Vp-p)