Panasonic wj-fs216 User Manual

Page of 30
-8-
MULTISCR:
Select this mode to monitor the camera pictures.
In MULTISCR mode you can perform the following
monitoring operations:
1. Camera picture
• Single spot picture
• Multi spot picture
• Single spot picture sequence
• Quad picture sequence
• Still multi spot picture
• Multi spot picture zoom
The menu content is different depending on the
selected mode.  (Compare MENU 1 OF 3 for MUL-
TIPLEX and MULTISCR mode below.) This is
described in more detail on the following pages.
    * MENU 1 OF 3 *
 DYNAMIC REC    OFF
 ALARM BUZZER   2S
 ALARM OUTPUT   2S
 REC MODE       4FIELDS
    * MENU 1 OF 3 *
 AUTO RESET       60S
 ALARM BUZZER      2S
 ALARM OUTPUT      2S
 MULTISCR CH SET *
MULTIPLEX mode
MULTISCR mode
Blinking
Blinking
4. Press the MENU button to return to monitoring.
• How to Operate the Menus
To select the desired item, press buttons 9-12 (
D
D
,
C
C
A
A
B
B
). Each time you press a button, the cursor
moves to the parameter of the selected item.
To set or select the desired parameter of the select-
ed item, press button 13 (
) or 14 (+).
Note:
Some items have a submenu (for example,
TITLE SETUP in MENU 2 OF 3).  To make set-
tings in a submenu, press button 15 (SET).
A. Setting up MENU 1 OF 3 in
MULTIPLEX mode
The content of MENU 1 OF 3 in MULTIPLEX mode
is as shown below.
    * MENU 1 OF 3 *
 DYNAMIC REC     OFF
 ALARM BUZZER     2S
 ALARM OUTPUT     2S
 REC MODE       4FIELDS
1. DYNAMIC REC
When  ON  is  selected for DYNAMIC REC, the
camera picture of a channel that receives an alarm
signal is recorded with more fields than normal. If
the alarm signal is received by multiple channels,
the pictures of all these channels are recorded.
1. Move the cursor to the DYNAMIC REC parameter.
9
10
11
12
2. Select ON or OFF.
ON:
The video signal of the channel that receives
the alarm signal is recorded with more fields
than normal.  If the alarm signal is received by
multiple channels, the pictures of all these
channels are recorded.
OFF:
The video at field rate are recorded from
channels number 1 to 16 regardless of any
channels receiving the alarm signal.
The factory setting is OFF.
• If you do not change any other parameters, press
the MENU button for 2 seconds.  The setup menu is
closed and the display returns to the monitoring
picture.
Before turning the power off, make sure to finalize
your settings by pressing the MENU button.
Otherwise the new settings will not be stored and
the previous settings remain in effect.  Turn the
power off after the monitoring picture appears on
the display.