Panasonic wj-sx650p User Manual

Page of 98
14
Notes:
• During the alarm acknowledgement (ACK) status (refer
to p. 68), event information is highlighted.
• When two or more alarm events have occurred, "
∗" is
displayed beside the event information.
• When an alarm whose display mode setting is OFF
occurs, "#" is displayed beside the event information.
• When auto tracking is scheduled for a camera event, "#"
is displayed beside the camera number.
• q to r can be displayed or hidden either altogether or
separately. Refer to p. 73 Lists of Operations and
Functions for details.
■ System Controller Display
Information
The following are the details on terminal mode operations.
For PS·Data operations, refer to p. 85 OPERATION (OTHER
THAN TERMINAL MODE) or the operating instructions of
system controllers. 
● WV-CU950/650
Monitor Number
Mon01 to 32: Monitor number
Camera Number
Cam001 to 999: Camera number
C-P0001 to 9999: Camera position number
Event 
HDR01 to 16: Recorder number
Pre000 to 256 (Lighting for 3.0 seconds): Preset position 
Note: Pre000 is the home position.
T-A0001 to 0256: Terminal alarm 
C-A0001 to 0999: Camera alarm 
R-A0001 to 0999: Recorder alarm 
S-A0001 to 1024: Serial alarm 
V-A0001 to 0999: Video loss
Busy
Busy + monitor number (Blinking)
A selected monitor is controlled by a higher-priority
operator. (Monitor busy)
Note: You cannot control the selected monitor, camera,
and recorder.
Busy + camera/recorder number (Blinking)
A selected camera or recorder is controlled by a high-
er-priority user. (Camera/Recorder busy)
Note:  You cannot control the selected camera or
recorder.
Status
Alarm (Blinking): Alarm is occurring.
Alarm (Lighting): Alarm is acknowledged. (Refer to p.
68.)
Memory + preset position number (Blinking for 3.0 sec-
onds): Preset position is registered.
Sequence Number
T-Seq01 to 32: Tour sequence number
G-Seq01 to 08: Group sequence number
Note: During sequence pause, "P" is displayed beside
the sequence number.
G-Seq09 to 32: Group preset number
Note: This sign disappears when the camera is con-
trolled.
Invalid (Blinking for 3.0 seconds): You have entered a
wrong value.
Not Avail (Blinking for 3.0 seconds):
• You cannot select a monitor because of lower priori-
ty.
• You have tried to activate a group sequence or
group preset on a monitor not assigned.
Prohibited (Blinking for 3.0 seconds): You have tried an
operation restricted by the operator's setting. 
Alarm Buzzer/Button Buzzer Setting
With the setting activated:
• Alarm buzzer can sound when alarms occur.
• Button buzzer can sound when a button is pressed or
an error message (Invalid, Prohibited, Level1 Fixed,
etc.) is displayed on the LCD.
Refer to the operating instructions of system controller
for settings.
t
y
r
q
w
e