Time Adjust Input
Time Adjust Output
37
Terminal
Duration
Remarks
Alarm Output 1 to
32
Until reset
Open Collector output,
24 V, 100 mA maximum
Alarm Recover
Input 1 to 16
100 or more
ms
Non-voltage make con-
tact output
1 second
• Open Collector out-
put, 24 V, 100 mA
maximum
• Signal is output every
hour on the hour.
100 or more
ms
• Non-voltage make
contact input
• Signal input is accept-
ed by up to ± 30 sec-
onds every hour on
the hour.
Time is adjusted on
the hour.
Note: "Alarm Recover Input 1 to 16" can be used as "Alarm
Monitor Reset". (Refer to p. 68.)
■ System Status Check
During connection procedures, system status can be
checked on 4 monitors.
The following examples are procedures to display the sys-
tem status on Monitor 1 to 4.
● WV-CU950/650
1. Select one of Monitor 1 to 4. (Refer to p. 57 Monitor
Selection.)
2. Press the MENU button repeatedly until "System Status"
appears on the LCD.
3. Press the F1 button. SYSTEM STATUS will be displayed
on Monitor 1 to 4.
Note: SYSTEM STATUS is displayed on a set of 4 monitors
(Monitor 5 to 8, Monitor 9 to 12...Monitor 29 to 32).
● WV-CU360C/CJ
1. Select one of Monitor 1 to 4. (Refer to p. 57 Monitor
Selection.)
2. Press the OSD and SYS S buttons at a time. SYSTEM
STATUS will be displayed on Monitor 1 to 4.
Note: SYSTEM STATUS is displayed on a set of 4 monitors
(Monitor 5 to 8, Monitor 9 to 12...Monitor 29 to 32).
Display example of SYSTEM STATUS
<Monitor 1>
<Monitor 4>
MON: Monitor number
LCN: Camera number or recorder number
MODE: Display mode of the monitor
• SETUP: System Setup
• HISTORY: Alarm History Display
KB: System controller or PC
OPE: User ID of the operator or timer event No.
PRI: Operator priority
• When SETUP MENU is displayed, "0" appears on
this area.
• During monitor lock, this area is highlighted.
Notes:
• Even while SYSTEM STATUS is being displayed on
monitors, normal operations and alarm control are avail-
able. However, you cannot check the camera or record-
ed images because black screen is displayed. It is rec-
ommended to use these monitors only to check SYS-
TEM STATUS.
• Up to 100 records of SYSTEM STATUS are saved in the
system. These records can be transmitted between PC
and this unit. (Periodical transmission is also available.)
For transmission, perform the serial command settings
in "Communication" – "Serial Command" of WJ-SX650
Series Administrator Console.
• To transmit SYSTEM STATUS records from the PC, refer
to Serial (RS-232C) Connector Command Reference
(PDF file on the supplied CD-ROM).
    SYSTEM STATUS
 
 MON  LCN  MODE       KB    OPE    PRI
  
  01  001  
  02  002             K1-1  123     01
  03  200                           03
  04  030                   /T001   99
  05  100  G08        PC    999     14
  06       SETUP      K1-4  5       00
  07       HISTORY    K3-2  10      02
  08  R16                   505     03
LCN:LOGICAL CAMERA NUMBER
LCN, MODE, KB and OPE parameters are highlighted 
for monitors during the alarm mode status.
LCN and MODE parameters are highlighted for monitors 
during the alarm ACK status.
    SYSTEM STATUS
 
 MON  LCN  MODE       KB    OPE    PRI
  
  25
  26  075             PSD   48      02
  27  105  T32              /T128   60
  28  002  T01        K6-3  3       05
  29  301  G32              12345   10
  30  401  G32              12345   10
  31  501  G32        K8-4  12345   10
  32  999
LCN:LOGICAL CAMERA NUMBER