CONNECTIONS
The following adjustment should be made by
qualified service personnel or system installers.
q Loosen the screws on the flange-back adjust-
ing ring.
w Turn the flange-back adjusting ring to the
desired position.
Caution:
Do not rotate the ring counterclock-
wise by force after it stops. If the ring is
rotated by force, the inner lens or CCD
image sensor may be damaged.
e Tighten the screws on the flange-back adjust-
ing ring.
FOCUS OR FLANGE-BACK ADJUSTMENT
Mounting the Lens
Caution:
Before you mount the lens, loosen the two
screws on the ring, and rotate this ring clock-
wise until it stops. If the ring is not at the end,
the inner glass or CCD image sensor may be
damaged.
q Mount the lens by turning it clockwise on the
lens mount of the camera.
w Connect the lens cable to the auto iris lens
connector on the side of the camera.
q
w
Screws
Flange-back
Adjusting Ring
Caution for Mounting the Lens
The lens mount should be a C-mount or CS-mount
(1”-32UN) and the lens weight should be less than
450 
g (0.99 lbs). If the lens is heavier, both the
lens and camera should be secured by using the
supporter.
The protrusion at the rear of the lens should be as
shown in the diagram.
CS-mount: Less than 8 mm (5/16”)
q e
w
Flange-back
Adjusting Ring
Screws
Caution:
Keep the POWER switch of the specified
monitor, Camera Extension Unit and Camera
Drive Unit in OFF position during connec-
tions.  If the power of these units are ON dur-
ing connections, the camera does not func-
tion due to protect circuit from misconnec-
tion.
Basic System
Connect the single coaxial cables between
the Camera and Camera Input Terminal of
Specified monitor or Camera Drive Unit. The
approx. maximum cable length is as:
Coaxial
Maximum
DC R/1 000 ft.
Cable
Cable
of Inner
Type
Length
Conductor
RG-59/U
200 m (660 ft)
Less than
30 
Ω
RG-6/U
500 m (1 650 ft) Less than
12 
Ω
The maximum DC resistance between the
camera and these units is 20 
Ω
.
Connection Diagram
Coaxial
Cable
2
1
2
3
4
1
2
3
4
GND
GND
STDBY
ALARM CONTROL
OUT
ALL
MODE
RESET
RECOVER
SPOT MONITOR CONTROL IN
REMOTE OUT
1
CAMERA INPUT
CAMERA
VTR
4
3
REC
OUT
AUDIO
IN
AUDIO
OUT
CAMERA
EXTENSION IN
PLAY
IN
OUT
IN
TIMING
SELECT
Video Monitor
WV-BM140
CAMERA
IN
VIDEO
OUT
AUDIO
OUT
VD/SYNC
IN
VD/SYNC
OUT
SIGNAL
GND
CAUTION
USE WITH SPECIFIED EQUIPMENT SEE
ITS MANUAL BEFORE CONECTING.
Camera
Video Monitor
Video
Audio
Camera Drive Unit
WV-PS11B
Caution:
To use the C-mount lens, the Lens
Mount Converter (C-mount adapter) WV-
AD20 should be used with the camera.
The mounting bracket can be fixed either on the
top or the bottom cover of the camera.
When mounting on the top cover of the camera,
detach the mount adapter from the bottom of the
camera cover and attach it on the top cover of the
camera.
1. Fix the camera mounting bracket on the wall
or ceiling to be installed by two screws (to be
procured locally).
2. Insert the camera fixing screw on the pan
head into the camera mounting adapter, and
tighten the pan head firmly.
3. Connect the camera and the monitor with the
coaxial cable (to be procured locally).
INSTALLING PROCEDURE