Panasonic WJ-RT416V User Manual

Page of 80
44
Connection with PS·Data systems
This is an example of connection when the unit is used together with the PS·Data devices.
If a connected system controller is PS·Data compatible, it is possible to operate this unit or connected devices using the sys-
tem controller.
Use the RS485 cable provided with the system controller.
Important:
• Terminate both devices on both ends of the connection. Refer to the respective operating instructions for the descriptions
of how to terminate. Termination of this unit can be set with the mode selection DIP switch on the rear panel. (See page
47.)
• When connecting a PS·Data compatible device, it is necessary to set each item of "PS.Data Setup" of "Communication
Setup" according to the system configuration.
• The following are available PS·Data compatible devices.
• System controller: WV-CU650 (Ver 2.10 or later)
• Data multiplex unit: WJ-MP204
• Matrix switcher: WJ-SX650 (Ver. 3.00 or later)
(Any other PS·Data compatible devices are not to be connected.)
When connecting a single unit with a controller
AUX IN
AUDIO OUT
IN
OUT
16
15
14
13
12
11
10
9
8
7
6
5
4
3
5
3
1
6
4
2
1
2
14
13
12
11
10
9
8
7
6
5
4
3
2
1
16
15
MONITOR1
MONITOR2
RS485(CAMERA)
MODE
1 2
DATA
10/100BASE-T
COPY1
ALARM IN/CONTOROL
AUDIO IN
SIGNAL GND
POWER
ON
OFF
AC IN
AUDIO IN/ALARM OUT
VIDEO
SERIAL
This unit
1
ON
2
Mode selection 
DIP switches
A
B
1
3
2
4
6
5
7
9
8
0
SYSTEM CONTROLLER
Controller
Termination: ON
Unit Address: 1
RS485 cable
(provided with the controller)
"PS.Data Setup" of "Communication Setup" 
on the Setup Menu
  • Unit Address (System):
1
  • Unit Address (Controller): 2