Panasonic WV-NF302 User Manual

Page of 20
10
Action at an alarm occurrence
The alarm action will be performed when the following alarms occur.
Alarm type
Terminal alarm: When connecting an alarm device such as a sensor to the EXT I/O connector on the of the
camera, the alarm action (camera action at an alarm occurrence) will be performed when the connected
alarm device is activated.
VMD alarm: When motion is detected in the set VMD area, the alarm action will be performed.
* VMD stands for "Video Motion Detection".
Command alarm: When a Panasonic alarm protocol (
☞ Setup Instructions) is received from the connected
device via a network, the alarm action will be performed. 
Action at an alarm occurrence
Display the [Alarm occurrence indication] button on the "Live" page. (
☞ page 6)
The alarm occurrence indication button will be displayed on the "Live" page at an alarm occurrence. 
Important:
When "Polling (30 sec)" is selected for "Alarm status update mode" (
☞ Setup Instructions), the alarm occurrence
indication button will be refreshed in 30-second intervals. For this reason, it may take a maximum of 30 seconds
until the alarm occurrence indication button is displayed on the "Live" page at an alarm occurrence. 
Notify of alarm occurrences to the device connected to the alarm connector
It is possible to output signals from the alarm connector on the rear of the camera and sound the buzzer when an
alarm occurs. The settings for the alarm output can be configured in the "Alarm output terminal setup" section of the
[Alarm] tab of the "Alarm" page. (
☞ Setup Instructions)
Transmit an image onto a server automatically
An alarm image can be transmitted at an alarm occurrence to the server designated in advance. The settings
required to transmit an alarm image to a server can be configured in the "Alarm image" section of the [Alarm] tab of
the "Alarm" page (
☞ Setup Instructions) and the [FTP] tab of the "Server" page (☞ Setup Instructions). 
Important:
Select "FTP error" for "Save trigger" on the [SD memory card] tab when using the SD memory card. When
"Alarm input" or "Manual" is selected for "Save trigger", an alarm image will not be transmitted at an alarm occur-
rence to the FTP server.
Notify of alarm occurrences by e-mail
Alarm mail (alarm occurrence notification) can be sent at an alarm occurrence to the e-mail addresses registered in
advance. Up to 4 addresses can be registered as recipients of the alarm mail. An alarm image (still picture) can be
sent with the alarm mail as an attached file. The settings for alarm mail can be configured in the "Mail notification"
section of the [Notification] tab of the "Alarm" page (
☞ Setup Instructions) and the [Mail] tab of the "Server" page 
(
☞ Setup Instructions). 
Notify of alarm occurrences to the designated IP addresses (Panasonic alarm protocol)
This function is available only when a Panasonic device, such as the network disk recorder, is connected to the sys-
tem. When "On" is selected for "Panasonic alarm protocol", the connected Panasonic device will be notified that the
camera is in the alarm state. The settings for Panasonic alarm protocol can be configured in the "Panasonic alarm
protocol notification" section of the [Notification] tab of the "Alarm" page. (
☞ Setup Instructions)