Environmental
Operating
Continuous operation: 10 °C to 35 °C at 10% to 80% 
relative humidity (RH), with 26 °C max dew point. De-rate 
maximum allowable dry bulb temperature at 1 °C/300 m 
above 900 m (1 °F per 550 ft).
NOTE: For information on supported expanded 
operating temperature range and configurations, see 
support.dell.com/manuals.
Storage
–40 °C to 65 °C (–40 °F to 149 °F) with a maximum 
temperature gradation of 20 °C per hour
Relative humidity
Operating
20% to 80% (noncondensing) at a maximum wet bulb 
temperature of 29 °C (84.2 °F)
Storage
5% to 95% at a maximum wet bulb temperature of 38 °C 
(100.4 °F)
Maximum vibration
Operating
0.26 Grms at 5–350 Hz (all operation orientations)
Storage
1.87 Grms at 10–500 Hz for 15 min (all six sides tested)
Maximum shock
Operating
One shock pulse in the positive z axis (one pulse on each 
side of the system) of 31 G for 2.6 ms in the operational 
orientation
Storage
Six consecutively executed shock pulses in the positive 
and negative x, y, and z axes (one pulse on each side of 
the system) of 71 G for up to 2 ms
Six consecutively executed shock pulses in the positive 
and negative x, y, and z axes (one pulse on each side of 
the system) of 32 G faired square wave pulse with 
velocity change at 270 inches/second (685 centimeters/
second)
Altitude
Operating
–15.2 m to 3048 m (–50 ft to 10,000 ft)
NOTE: For altitudes above 2950 ft, the maximum 
operating temperature is derated 1ºF/550 ft.
Storage
–15.2 m to 10,668 m (–50 ft to 35,000 ft)
Airborne Contaminant Level
Class
G1 as defined by ISA-S71.04-1985
8