SCSI cable length
The maximum allowable cable length for a low-voltage differential SCSI bus, 
including all internal and external cables, is specified as follows:
If you have more than two devices on the LVD bus, the maximum 
allowable length is 39 feet (12 meters).
If you are making a point-to-point connection (target and initiator only), 
the maximum length is 82 feet (25 meters).
To determine the cable length of the bus, measure the lengths of all 
external SCSI cables. Add those lengths together. To that sum, add 26.8 
inches (68 centimeters) for the internal SCSI cable length.
SCSI terminator requirements 
If the autoloader or the tape drive is the last device on the SCSI bus, you must 
install an external, wide LVD terminator on the unused SCSI connector. Do not 
use internal terminators to terminate the autoloader or the tape drive. We 
recommend using a SCSI-3 type SE/LVD multi-mode terminator.
Important
To comply with the safety and regulatory agency standards 
for the autoloader, all SCSI cables you use with the 
autoloader must be correctly shielded.
Important
The autoloader and the tape drive are independent SCSI 
devices on the same SCSI bus. As a result, when they are 
connected to the initiator, there are a minimum of three 
devices attached to the SCSI bus. Therefore, the 
maximum allowable cable length is 39 feet (12 meters).
Important
We recommend using active termination. Testing has 
shown that older passive termination does not provide 
rising edge transitions that are fast enough or clean 
enough at fast SCSI speeds.