The latest error code (Warning Status) appears in the Main Menu when an abnormality occurs in the projector. Error 
details are as follows:
Warning Status
Error Code
Meaning
1
Lamp 1 does not turn on.
2
Accumulated lamp time for Lamp 1 has exceeded 2000 hours.
6
Lamp 1 goes off during projection.
8
Abnormally high temperature in the projector.
9
Abnormally high temperature around the intake vent.
A
Abnormally high ambient temperature around the lamp.
15
The lamp cover is open.
30
Trouble with CPU circuit board.
31
Trouble with MAIN circuit board.
32
Trouble with DD-RB circuit board.
33
Trouble with DD-G circuit board.
40
FAN1 (the cooling fan for Lamp 1) has stopped.
41
FAN2 (the cooling fan for Lamp 2) has stopped.
42
FAN3 (the cooling fan for overall exhaust/prism) has stopped.
43
FAN4 (the auxiliary cooling fan for exhaust) has stopped.
44
FAN5 (the cooling fan for the lighting system (PCS)) has stopped.
45
FAN6 (the cooling fan for the device) has stopped.
46
FAN7 (the cooling fan for the MAIN circuit board) has stopped.
47
FAN8 (the cooling fan for the DD circuit board) has stopped.
48
FAN9 (the cooling fan for the power supply of the circuit) has stopped.
49
FAN10 (the cooling fan for the power supply of Lamp 1) has stopped.
4A
FAN11 (the cooling fan for the power supply of Lamp 2) has stopped.
50
Trouble with mechanical shutter.
51
Lamp 2 does not turn on.
52
Accumulated lamp time for Lamp 2 has exceeded 2000 hours.
56
Lamp 2 goes off during projection.